English
M3 Power
  • Dynaco M3 Power

For inside and outside environments

  • Standard dimension up to 39' W X 18' H
  • Opening Speed: Up to 96" Per Second
  • Wind Resistance: 60 MPH for an 18’ wide door
  • Colours

    blanc 9010 White

    bleu 5002 Blue

    gris 7035 Grey

    jaune 1003 Yellow

    noir 9005 Black

    orange 2004 Orange

    rouge 3000 Red

    vert 6005 Green

    Standard Dimensions

    39' W x 18' H

    Standard Operating Speed

    31.2 in/s

    Operating Type

    Gear driven, push-pull movement

    Side Guide

    Made of structural channels of 3 15/16" x 2" x 1/8" in galvanized steel.

    Inner Side Guide

    Polyethylene (PE-UHMW 1000); outer section 7/8” x 1 9/16”, on springs. Galvanized side covers included.

    Drum

    In steel, diameter 5 1/2" x 1/8", shafts in steel.

    Door Curtain

    Reinforced PVC (27 oz/sq.yd). Available in different colors and provided with side sealing zippers; soft bottom edge design.

    Motor

    Without brake, with 4 poles, controlled by a variable speed drive. Power : 2 HP for a door surface up to 61 sq.yds; 3 HP (larger surface). Protection degree NEMA 4.

    Gearbox

    Size 63 for a motor of 2 HP and gear reduction ratio 1/15; size 90 for 3 HP.

    Detectors

    An infrared photocell installed inside the side guide and detecting the presence of a pedestrian or a vehicle. Upon activation, it opens the door immediately and keeps it open as long as the presence is detected. Height of the photocell: 12” from the floor. (Optional: up to maximum 24” from the floor). A bottom edge detector opens the door when it hits an obstacle during the closing cycle. This detector is positioned at the bottom part of the curtain.

    Power Supply

    Standard: single phase 208-230 VAC, three phase 208-230 VAC, three phase 460 VAC. Optional: three phase 575 VAC Frequency: 50-60 Hz. Circuit breakers to be provided by the customer: 16A for a motor of 2 HP; 25 A for 3 HP..

    Space Requirements

    All indicated dimensions are net: the additional space necessary for mounting and maintenance has to be taken into account. Reduced dimensions upon request.
    • Curtain made of reinforced PVC vinyl
    • Infrared photocell in side guides
    • Soft bottom edge
    • Pneumatic bottom edge detector
    • Maximum standard dimension up to 39' x 18'
    • High wind resistance
    • Operating speeds from 48" to 96" per second
    • Gear driven, push pull operation
    • Recommended for high traffic areas
    • Manufacturing
    • Production areas
    • Transportation
    • Distribution
    • Automotive
    • Whenever wind protection is required

    Colours

    Colours

    blanc 9010 White

    bleu 5002 Blue

    gris 7035 Grey

    jaune 1003 Yellow

    noir 9005 Black

    orange 2004 Orange

    rouge 3000 Red

    vert 6005 Green

    Features

    Standard Dimensions

    39' W x 18' H

    Standard Operating Speed

    31.2 in/s

    Operating Type

    Gear driven, push-pull movement

    Side Guide

    Made of structural channels of 3 15/16" x 2" x 1/8" in galvanized steel.

    Inner Side Guide

    Polyethylene (PE-UHMW 1000); outer section 7/8” x 1 9/16”, on springs. Galvanized side covers included.

    Drum

    In steel, diameter 5 1/2" x 1/8", shafts in steel.

    Door Curtain

    Reinforced PVC (27 oz/sq.yd). Available in different colors and provided with side sealing zippers; soft bottom edge design.

    Motor

    Without brake, with 4 poles, controlled by a variable speed drive. Power : 2 HP for a door surface up to 61 sq.yds; 3 HP (larger surface). Protection degree NEMA 4.

    Specifications

    Gearbox

    Size 63 for a motor of 2 HP and gear reduction ratio 1/15; size 90 for 3 HP.

    Detectors

    An infrared photocell installed inside the side guide and detecting the presence of a pedestrian or a vehicle. Upon activation, it opens the door immediately and keeps it open as long as the presence is detected. Height of the photocell: 12” from the floor. (Optional: up to maximum 24” from the floor). A bottom edge detector opens the door when it hits an obstacle during the closing cycle. This detector is positioned at the bottom part of the curtain.

    Power Supply

    Standard: single phase 208-230 VAC, three phase 208-230 VAC, three phase 460 VAC. Optional: three phase 575 VAC Frequency: 50-60 Hz. Circuit breakers to be provided by the customer: 16A for a motor of 2 HP; 25 A for 3 HP..

    Space Requirements

    All indicated dimensions are net: the additional space necessary for mounting and maintenance has to be taken into account. Reduced dimensions upon request.

    Other Details

    • Curtain made of reinforced PVC vinyl
    • Infrared photocell in side guides
    • Soft bottom edge
    • Pneumatic bottom edge detector
    • Maximum standard dimension up to 39' x 18'
    • High wind resistance
    • Operating speeds from 48" to 96" per second
    • Gear driven, push pull operation
    • Recommended for high traffic areas

    Applications

    • Manufacturing
    • Production areas
    • Transportation
    • Distribution
    • Automotive
    • Whenever wind protection is required


NEED INFORMATION ?